125000455 - A25 ALARM VOLUMETRIC SURVEILLANCE NOT WORKING

When the alarm is activated, the volumetric surveillance does not work
Results of the tests
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Volumetric surveillance can be excluded voluntarily from the operation of the system See    See E7015 ALARM.
Connect the diagnostic equipment (Examiner Plus or Smart) to the diagnostic socket and check whether there are faults in the CAN network
Continue to Step 2Faults present in the CAN networkRepair the connections on the nodes concerned
2CHECK ON VOLUMETRIC SENSORSAll OKProblems metOperation

Check, in order:

  • Operation of volumetric sensors;
  • Connections between sensors and Body Computer See    See E7015 ALARM
Continue to Step 3Sensor faultyReplace sensors Op. 5580E50
Connections brokenRestore the connections See    See E7015 ALARM
3CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosis.