125000624 - L03 CLIMATE CONTROL AIR FLOW IRREGULAR

The fan is not working properly.
Results of the tests
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the diagnostic equipment (Examiner Plus or Smart) to the diagnostic socket.Check that there are no faults in the climate control system control unitContinue to Step 2An error is detected in the control unitContinue following the instructions for the diagnostic equipment
Communication lost with control unit - CAN line errorRestore connection between climate control system control unit and body computer See    See E6020 AIR CONDITIONING
2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the diagnostic equipment (Examiner or other instruments), carry out the active diagnosis for the electric fan at the different speedsContinue to Step 3Electric fan connection faultRestore the correct connection See    See E6020 AIR CONDITIONING
Electric fan faultyReplace the electric fan Op.    Op. 5040C30 FAN MOTOR - R+R
3CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosis.