125000627 - L12 CLIMATE CONTROL TOO COLD

The control button operates the passenger compartment air fan normally, but the temperature of the air is not correct.
Results of the tests
1AIR TEMPERATURE CHECKAll OKProblems metOperation
Check the temperature of the air at the ventsContinue to Step 8Ambient temperature at the ventsContinue to Step 2
Temperature at the vents higher than desiredContinue to Step 3
2CHECKING SYSTEM PRESSUREAll OKProblems metOperation
Connect the climate control system to the recharging equipment and check the system pressuresContinue to Step 8High and low pressure values below correct figuresRepressurize the system Op.    Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM DEHYDRATE AND RECHARGE
High and low pressure values above correct figuresContinue to Step 3
Low pressure value correct, but high pressure value above correct figure (rapid compressor cycle as engine rpm increases)Continue to Step 4
Low pressure value high and high pressure value below correct figureReplace the compressor Op.    Op. 5040A20 AIR CONDITIONER COMPRESSOR - R+R - INCLUDES FLUID LEVEL CHECK AND TOP UP IF NECESSARY
High and low pressure vaules do not alter when the air conditioning is activated.Replace the compressor Op.    Op. 5040A20 AIR CONDITIONER COMPRESSOR - R+R - INCLUDES FLUID LEVEL CHECK AND TOP UP IF NECESSARY
3CONDENSER FAN CHECKAll OKProblems metOperation
Check that the fan cools the condenser correctly.Continue to Step 4Electric fan defectiveReplace the electric fan Op.    Op. 5040C30 FAN MOTOR - R+R
4CIRCUIT LOADING CHECKAll OKProblems metOperation
Check that the system loading is not excessive.Continue to Step 5System loading excessive.Restore the correct loading Op.    Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM DEHYDRATE AND RECHARGE
5COOLANT CIRCUIT OBSTRUCTION CHECKAll OKProblems metOperation
1.9 JTD 16VTwo-zone climate control systemCheck that the pipes and the filter are not obstructed.Continue to Step 6Pipe from condenser to drier filter obstructedReplace the pipe Op. 5040A52
Filter obstructedReplace the filter Op.    Op. 5040A44 AIR CONDITIONER DEHYDRATING FILTER/ACCUMULATOR - R+R
2.0 JTS3.2 V6Two-zone climate control systemCheck that the pipes and the filter are not obstructed.Continue to Step 6Pipe from compressor to condenser obstructedReplace the pipe Op.    Op. 5040A50 PIPE FROM COMPRESSOR TO AIR CONDITIONER CONDENSER - R+R
Pipe from condenser to filter obstructedReplace the pipe Op. 5040A52
Pipe from filter to evaporator obstructedReplace the pipe Op. 5040A56
Filter obstructedReplace the filter Op.    Op. 5040A44 AIR CONDITIONER DEHYDRATING FILTER/ACCUMULATOR - R+R
6CONDENSER CHECKAll OKProblems metOperation
Check that the condenser is not blocked.Continue to Step 7Condenser blockedReplace the condenser Op.    Op. 5040A40 AIR CONDITIONER CONDENSER - R+R
7EXPANSION VALVE CHECKAll OKProblems metOperation
Check the operation of the expansion valve.Continue to Step 8Expansion valve defectiveReplace the expansion valve Op.    Op. 5040B30 EXPANSION VALVE (TUBE ORIFICE) - R+R
8CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosis.