125000629 - L16 CLIMATE CONTROL RECIRCULATION NOT WORKING

Climate control system recirculation does not work in every state (normal/automatic)
Results of the tests
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the diagnostic equipment (Examiner Plus or Smart) to the diagnostic socket.Check that there are no faults in the climate control control unit.Continue to Step 2An error is detected in the control unitContinue following the instructions for the diagnostic equipment
Communication lost with control unit - CAN errorRestore connection between climate control system control unit and body computer See    See E6020 AIR CONDITIONING
2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the diagnostic equipment (Examiner or other instruments) carry out active diagnosis on the recirculation motorContinue to Step 3Recirculation motor faulty connectionRestore the correct connection See    See E6020 AIR CONDITIONING
Recirculation motor faultyReplace the recirculation motor Op.    Op. 5040D52 AIR INLET AND RECIRCULATION FLAP ACTUATOR - R R
Recirculation motor flap faultyReplace the recirculation motor flap Op.    Op. 5040D52 AIR INLET AND RECIRCULATION FLAP ACTUATOR - R R
3CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosis.