125000630 - L17 CLIMATE CONTROL RECIRCULATION AUTOMATIC MODE NOT WORKING

The recirculation is not closed in automatic mode when there is pollution.
Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation
Check that the flap works when the recirculation button is pressedContinue to Step 1Motor not workingContinue to Step 2
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the Examiner and check for errors at the climate control node.Carry out the recirculation motor test in active diagnosisIf it is not activated, check the recirculation motor wiring See    See E6020 AIR CONDITIONINGContinue to Step 2Faulty wiringRenew the wiring See    See E6020 AIR CONDITIONING
2CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the Examiner Plus or Smart diagnostic equipment and check that the recirculation flap is working properly in automatic mode by selecting active diagnosis and carrying out the pollution sensor test.If the result is negative, carry out theContinue to Step 3Passenger compartment air pollution sensor defectiveReplace sensor Op.    Op. 5010D72 AIR QUALITY SENSOR - R R FOLLOWING CIRCUIT CHECK
Pollution sensor wiring brokenRenew the wiring See    See E6020 AIR CONDITIONING
3CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the recirculation flap is working properly by carrying out the pollution sensor test again with the Examiner in Active Diagnosis.Check that the fault is no longer present.End of diagnosisFault persistsReplace the climate control system control unit Op.    Op. 5040D15 CONTROL UNIT WITH AUTOMATIC DUEL ZONE AIR CONDITIONER KNOBS AND BUTTONS R R