125000672 - P10 CENTRAL LOCKING / NOT WORKING

When the central door locking is operated with the key or remote control (if present), the doors do not open and do not close
Results of the tests
1FUSE CHECKAll OKProblems metOperation
Check condition of fuses See    See E3040 CENTRAL LOCKINGContinue to Step 2Fuse brokenReplace the fuse, after having searched for the cause of the problem
2CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Check the opening/closing of the doors through active diagnosisContinue to Step 6The doors do not open/closeContinue to Step 3
3ELECTRICAL CIRCUIT CHECKAll OKProblems metOperation
Check the electrical connection between the Body Computer Node and the door locks See    See E3040 CENTRAL LOCKINGContinue to Step 4Electrical connector in door lock not properly connectedConnect the electrical connector properly to the door lock
Connection broken or not insulatedRestore continuity/insulation of the electrical connection See    See E3040 CENTRAL LOCKING
4CHECKING ELECTRICAL SIGNALAll OKProblems metOperation
Disconnect the electrical connector for the door lock and check for the opening command signalContinue to Step 5Opening command signal absent.Continue to Step 6
5Continue as instructed by the testerAll OKProblems metOperation
Check that the fault is no longer present.End of diagnosisThe fault persistsReplace the door lock Op.    Op. 7005N21 FRONT SIDE DOOR LOCK MOTOR-LOCK ASSEMBLEY-R R
6CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer present.End of diagnosisThe fault persistsReplace the body computer node Op.    Op. 5505A32 BODY COMPUTER - R R