125000674 - P14 BOOT OPENING/CLOSING NOT WORKING

When the boot is opened/closed using the key or opened using the button in the control panel, the boot does not open and does not close
Results of the tests
1FUSE AND RELAY CHECKAll OKProblems metOperation
Check the condition of the fuses and relays See    See E3045 BOOT AND FUEL FLAP OPENINGContinue to Step 2Components faultyReplace the component involved (if a fuse is involved, search for the cause of the problem)
2CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Check the opening/closing of the boot through active diagnosisContinue to Step 6The boot does not open/closeContinue to Step 3
3ELECTRICAL CIRCUIT CHECKAll OKProblems metOperation
Check the electrical connection between the body computer node, driver''s door node and the boot lock. See    See E3045 BOOT AND FUEL FLAP OPENINGContinue to Step 4Electrical connector in boot lock not correctly connectedConnect the electrical connector to the boot lock correctly
Connections broken or not insulatedRestore continuity/insulation of the electrical connection See    See E3045 BOOT AND FUEL FLAP OPENING
4CHECKING ELECTRICAL SIGNALAll OKProblems metOperation
Disconnect the boot lid lock electrical connector and check for a opening command signal.Continue to Step 5Opening command signal absent.Continue to Step 7
5Continue as instructed by the testerAll OKProblems metOperation
Check that the fault is no longer present.End of diagnosisThe fault persistsReplace the boot lock motor Op.    Op. 7015B70 TAIL-GATE LOCK MOTOR - R R AND CHECK LOCK SUPPLY LINE
6CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Press the button in the dashboard and check, in the parameters ambient, at the Driver''s Door Node, that the boot lid opening button status changesContinue to Step 9There is no change in the statusContinue to Step 7
7ELECTRICAL CIRCUIT CHECKAll OKProblems metOperation
Check the electrical connection between the switch in the dashboard and the Driver''s Door Node See    See E3045 BOOT AND FUEL FLAP OPENING. Also check that the switch in the dashboard is working properly.Continue to Step 8Connections broken or not insulatedRestore continuity/insulation of the electrical connection See    See E3045 BOOT AND FUEL FLAP OPENING
Switch faultyReplace the switch in the dashboard Op. 7015B80
8REPLACING DRIVER''S DOOR NODEAll OKProblems metOperation
Replace the Driver''s Door Node Op. 5505A42and check that the fault is no longer presentEnd of diagnosisThe fault persistsRestore the Driver''s Door Node and replace the Body Computer Node Op.    Op. 5505A32 BODY COMPUTER - R R
9CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer present.End of diagnosisThe fault persistsReplace the body computer node Op.    Op. 5505A32 BODY COMPUTER - R R