125000763 - 1080BA UPSTREAM LAMBDA SENSOR OPERATION CHECK

Disconnect the negative battery terminal

  • Disconnect the negative battery terminal.
  • Disconnect the electrical connection for the upstream Lambda sensor.
  • Check that the heater resistance measured between pins 3 and 4 is between 3.5 and 4.5 Ohm at 20 °C.
Disconnect the electrical connection for the upstream Lambda sensor
DescriptionConnector
-Lambda sensor downstream of the post-converter See K17 LAMBDA SENSOR DOWNSTREAM OF POST-CATALYZER ( ENGINE )
Check that the heater resistance corresponds to the recommended value
MeasurementValue
-Heater resistance (ohm)Pins 3 - 4 at 20°C4.0 ± 0.5