125000807 - 5580CF SATELLITE SENSOR CHECK

Disconnect the connector for the satellite sensor at the line concerned and connect the special bridges following the instructions.Connect the Examiner to the diagnostic socketCancel the errors and check that they have disappeared.If the error persists, search for the fault in the wiring or in the control unit.If the error does not occur again, the fault should be sought in the satellite sensor.Reconnect the connector.