125001086 - 1072D22 AIR FLOW SWITCH CONTROL ACTUATOR R R

Removing ( Refitting )

  • Make sure that the ignition key is in the OFF position, then disconnect the battery terminal (-).
DescriptionConnector
-Battery See A001 Battery

1. Disconnect the electrical connection from the switching control actuator enablement solenoid valve.
DescriptionConnector
1Variable geometry solenoid valve See L15 VARIABLE GEOMETRY CONTROL SOLENOID
2. Disconnect the vacuum intake pipe from the air flow switching device actuator and release it from the fastening on the latter.3. Disconnect the air flow switching device actuator linkage.

  • Undo the bolts (1a) and remove the air flow switching device control actuator (1b).
Refitting ( Removing )