125001088 - 1072D20 AIR FLOW SWITCHING DEVICE ACTUATOR - R+R WITH MODULAR MANIFOLD DISCONNECTED

Removing ( Refitting )

  • Disconnect the vacuum intake pipe from the air flow switching device actuator and release it from the fastening on the latter.
  • Disconnect the air flow switching device actuator linkage.
  • Undo the bolts (3a) and remove the air flow switching device control actuator (3b).
Refitting ( Removing )

  • Place the air flow switching device control actuator in position.
  • Connect the air flow switching device actuator linkage.
  • Connect the vacuum intake pipe from the air flow switching device actuator and secure it to the latter.