125002611 - 1056B48 TIMING VARIATOR SOLENOIDS - R + R

Removing ( Refitting ) Ensure that the ignition key is in the OFF postition, then disconnect the battery negative terminal.
NameConnector
-Battery    See A1B BATTERY ( CONNECTORS )
Proceed with the removal    Op. 1016A40 IGNITION COIL COVER ON CYLINDER HEAD- R+R.1. Disconnect the electrical connection from the variable valve timing electro-magnet.
NameConnector
1Timing variator actuator    See N76 TIMING VARIATOR ACTUATOR ( ENGINE )
2. Undo the bolts (2a) and remove the variable valve timing electro-magnet (2b).
Refitting ( Removing ) Refit the variable valve timing electro-magnet and secure by tightening the bolts to the recommended torque.
FasteningComponentØValue(daNm)
-BoltADVANCE VARIATOR SOLENOIDSM7(Intake manifold side) 1.4 ÷ 1.7
Connect the electrical connection to the variable valve timing electro-magnet.Proceed with the refitting    Op. 1016A40 IGNITION COIL COVER ON CYLINDER HEAD- R+R.Connect the battery terminal (-).