2398824 - K38 MILOMETER/TRIP METER FLASHING

.
Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the Examiner diagnostic instrument and check, in the 'Control Units Test' environment, 'Other Systems' Group, 'Proxi Alignment Procedure' systems that the Instrument Panel Node is aligned. Continue to Step 5Impossible to carry out Proxi alignmentContinue to Step 2
Alignment not carried outCarry out Proxi alignment
2CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the Examiner diagnostic equipment and check, in the Instrument Panel Node ambient, that there are no errors and the following parameters are present. Continue to Step 7Impossible to connect with the instrument panel nodeContinue to Step 3
There are errors Continue to Step 6
3ELECTRICAL POWER SUPPLY CHECKAll OKProblems metOperation
Check that the Instrument Panel Node electrical power supply is correct See   E4010  INSTRUMENT PANEL Continue to Step 4Positive and/or earth electrical power supply faultyRepair and/or replace the defective component (if a fuse is involved, search for the cause of the problem)
4CHECK ELECTRICAL CONNECTIONSAll OKProblems metOperation
Check the wiring/electrical connections for the Instrument Panel Node, in particular making sure that each individual pin is correctly connected and inserted in its housingContinue to Step 5Wiring and/or electrical connections not workingRestore the wiring and/or damaged electrical connections
5CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the Examiner, check the possibility of connecting with the Instrument Panel Node Continue to Step 2Impossible to connect with the control unitReplace the instrument panel control unit Op. 5560B11
6ERRORS CHECKAll OKProblems metOperation

Using the Examiner in the Instrument Panel Node ambient, check that one or more of the following errors is not present:

  • CAN line
  • EEPROM
Continue to Step 7No additional information and/or BUS off detected.Continue according to the instructions for the diagnostic equipment
EEPROM faultyReplace the instrument panel control unit Op. 5560B11
7CHECK WITH ACTIVE DIAGNOSISAll OKProblems metOperation
Using the Examiner in the active diagnosis ambient, check that the Autotest function is activatedContinue to Step 8The function in question is not controlled by active diagnosisReplace the instrument panel control unit Op. 5560B11
8CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisThe fault persistsContinue to Step 1