2398879 - L15 CLIMATE CONTROL NOT HEATING

The climate control works properly and sends air in accordance with the set flows, but this air does not ensure the required heating.
Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation
Check coolant level is within pre-set values.Continue to Step 3Engine coolant level insufficientRestore correct level, check for leaks in the system.
1CHECKING DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the examiner and check for errors at the air mixing motorsContinue to Step 4Air mixing motor errorContinue to Step 2
2ELECTRICAL CIRCUIT CHECKAll OKProblems metOperation
Check the continuity/insulation of the electrical connection for the air mixing motors See   E6020  AIR CONDITIONING Continue to Step 3Electrical conection broken or not insulated.Restore continuity/insulation of electrical connection See   E6020  AIR CONDITIONING
3CHECKING CORRECT OPERATION USING TESTERAll OKProblems metOperation
Check that the errors at the air mixing motors do not persist (after the self-learning procedure)End of diagnosisAir mixing motor errorReplace the mixed air motor
4CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsChange the climate control system node