2398906 - V10 SUN ROOF WATER PENETRATION

There is water penetration through the sun roof;
the roof in question is not equipped with drainage pipes therefore any water penetration is due to faults in the seals and/or incorrect matching
Results of the tests
1SEAL CHECKAll OKProblems metOperation
Check the condition of the perimeter water seal making sure that it is fitted correctly Continue to Step 2Seal faultyReplace the seal fitting it correctly
2REAR GLASS CHECKAll OKProblems metOperation
Check the condition of the sealant matching between the fixed rear glass and the roof frame Continue to Step 3Matching/sealant not correctRestore correct coupling
3CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer present.End of diagnosisFault persistsContinue to Step 4
4ROOF FITTING CHECKAll OKProblems metOperation
Check that the roof is correctly fitted in the special housing and that there are no visible areas where the sealant is not correct Continue to Step 3Incorrect fittingRefit correctly