2401066 - 5580HB Check operation of Parking Sensor System
After having connected at least the Examiner negative supply lead to the vehicle earth and having switched it on, switch to Voltmeter mode and connect the multimeter lead (black probe) to the vehicle chassis.Use the red volmeter probe to check for the following at the control unit junction box:
- correct power supply, first positive and then negative
- Enablement for towing.
The dashed line in the image
above is determined by sensor activation. Position the red voltmeter probe alternately
at the electrical signal output signal leads of the various sensors
alternately.Press the Start button on the Examiner with
the values selected previously.The image values that appear should be assessed with
a tolerance of around 20% and should be similar to the following
image.
If the electrical signal sent
to the sensor control unit is different from the above image, the
individual sensor is not operating correctly or the control unit input
is defective.