2400462 - 5010A08 (DUPLEX) supply and return PIPE between engine and heater - R.R.
Removing ( Refitting ) - 5530B10 battery - r+rPosition a suitable container for recovering the coolant fluid.Mark the position of the heater supply and return connectors. 1. Loosen the bands retaining the duplex pipe.2. Disconnect the duplex pipe from the connectors and allow the coolant to drain into a suitable container.
Refitting
(
Removing
)
Check that the duplex pipe is not damaged
and that there are no cracks which would affect the seal.Reposition the duplex pipe and connect
it to the connectors and tighten the retaining bands.
Take care to follow the marks made previously. |