2400232 - 1060G10 flow meter - r r

Removing ( Refitting ) Ensure that the ignition key is in the OFF position, then disconnect the negative battery terminal (-).

NameConnector
-Battery  A1B 
1. Disconnect the electrical connection from the air flow meter.

NameConnector
1Air flow meter  K41 
2. Loosen the band and disconnect the the turbocharger air inlet sleeve from the rigid pipe, air flow meter side.3. Undo the bolts (3a) and remove the air flow meter (3b).
Refitting ( Removing ) Refit the air flow meter in its seating and secure it with its bolts.Connect the air intake sleeve to the turbocharger, air flow meter side, and tighten the band.Connect the electrical connection to the air flow meter.Connect the negative (-) battery terminal.