2400234 - 1060G16 pressure relief sensor - r r

Removing ( Refitting ) Ensure that the ignition key is in the OFF position, then disconnect the negative battery terminal (-).

NameConnector
-Battery  A1B 
1. Disconnect the electrical connection from the air flow meter.

NameConnector
1Air flow meter  K41 
2. Loosen the band and disconnect the the turbocharger air inlet sleeve from the rigid pipe, air flow meter side.
1. Remove the air filter (1a) complete with air flow meter (1b) by releasing from the underlying pins and then from the rear fastenings.
1. Release the electrical wiring (1a) from the band (1b) and move it aside.2. Disconnect the electrical connection from the excess pressure sensor.

NameConnector
2Turbocharging sensor  K82 
3. Undo the bolt (3a) and remove the over-pressure sensor (3b).
Refitting ( Removing ) Replace the excess pressure sensor in its housing and fix it using the bolt.Connect the electrical connection to the excess pressure sensor. Place the electrical wiring back in its housing and fix it to the bands.Replace the air filter, complete with air flow meter, in its housing.Connect the air intake sleeve to the turbocharger, air flow meter side, and tighten the band.Connect the electrical connection to the air flow meter.Connect the negative (-) battery terminal.