2400240 - 1060G80 ds electric injection control unit - r r

Removing ( Refitting ) Ensure that the ignition key is in the OFF position, then disconnect the negative battery terminal (-).

NameConnector
-Battery  A1B 
1. Disconnect the electrical connection from the air flow meter.

NameConnector
1Air flow meter  K41 
2. Loosen the band and disconnect the the turbocharger air inlet sleeve from the rigid pipe, air flow meter side.
1. Remove the air filter (1a) complete with air flow meter (1b) by releasing from the underlying pins and then from the rear fastenings.
1. Disconnect the electrical connections (1a) and (1b) from the diesel electronic injection system control unit.

NameConnector
1aEngine management control unit  M10A 

NameConnector
1bEngine management control unit  M10B 
1. Undo the bolts (1a) and remove the diesel electronic injection system control unit (1b).
Refitting ( Removing ) Place the diesel electronic injection system control unit back in its housing and secure it tightening the bolts to the recommended torque.

FasteningComponentØValue(daNm)
-----
Connect the electrical connections to the diesel electronic injection control unit.Place the air flow meter in its housing on the air filter and secure it using the bolts.Replace the air filter, complete with air flow meter, in its housing.Connect the air intake sleeve to the turbocharger, air flow meter side, and tighten the band.Connect the electrical connection to the air flow meter.Connect the negative (-) battery terminal.