2400393 - 3380A10 handbrake lever - r+r

Removing ( Refitting ) Ensure that the ignition key is in the OFF position, then disconnect the negative battery terminal (-).

NameConnector
-Battery  A1B 
Proceed with removal  - 3380A44  handbrake/linkage protection - r+r Proceed with removal  - 7040L20  tunnel trim - r r1. Loosen adjustment nut (1a), then disconnect cables (1b) from the mount.2. Disconnect the electrical connection from the handbrake 'on' warning light switch.

NameConnector
2Handbrake switch  I40 
3. Undo the bolts (3a) and remove the handbrake lever (3b).
Refitting ( Removing ) Fit the handbrake lever and tighten the bolts to the specified torque.

FasteningComponentØValue(daNm)
-BoltHANDBRAKE LEVERM8(Bodyshell side ) 2.4 ÷ 3.0
Connect the electrical connection to the handbrake 'on' warning light switch.Connect the cables to the mount. Proceed with refitting  - 7040L20  tunnel trim - r r . Proceed with refitting  - 3380A04  handbrake - check travel . Proceed with refitting  - 3380A44  handbrake/linkage protection - r+r . Connect the negative (-) battery terminal.