3308731 - S51 CLIMATE CONTROL SYSTEM NOISY' / (IN PASSENGER COMPARTMENT)
The climate control is working properly, but there is excessive noise coming from the distributor duct assembly| Results of the tests | ||||
| 1 | CHECKING ELECTRIC FAN | All OK | Problems met | Operation | 
|---|---|---|---|---|
| Check
the climate control electric fan. In particular, ascertain: 
 | Continue to Step 2 | Fan dirty | Clean the fan casing and all the ducts | |
| Electric motor noisy, fan unbalanced | Replace the electric fan Op. 5040C30 | |||
| 2 | ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Using the diagnostic equipment (Examiner or other instruments), carry out (in the climate control control unit ambient) the active diagnosis of the: 
 | Continue to Step 3 | Electric fan operation irregular | Replace the electric fan Op. 5040C30 | |
| One of the motors operation is irregular | Replace one of the motors (see Assembly 5040D) | |||
| Motor flap operation irregular | Replace the flap Op. 5040C24 | |||
| Presence of foreign bodies or damaged parts inside the duct distributor assembly | Overhaul the duct distributor assembly Op. 5040C24 | |||
| 3 | CHECKING THE AIR DUCTS | All OK | Problems met | Operation | 
| Check that the air ducts inside the dashboard and the vents are intact and that there are no foreign bodies which could cause noise | Continue to Step 4 | Ducts obstructed or damaged | Restore the operation of the ducts and the vents (see Assembly 5010B) | |
| 4 | HECK ON CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | End of diagnosis | Fault persists | Search for the fault starting from another symptom' | |