3308664 - K55 CODE FAILURE WARNING LIGHT OFF / (DO NOT CARRY OUT INITIAL TEST)
During starting, the CODE warning light does not come on (it should come on for 0.7 seconds to indicate that the initial control unit test has been carried out, and it should then go out)| Results of the tests | ||||
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
|---|---|---|---|---|
| Connect diagnostic equipment (Examiner or other instruments) to the diagnostic socket.Check that there is regular dialogue with the CODE control unit | Continue to Step 2 | Lack of dialogue with the control unit | Refit: 
 | |
| An error is detected in the control unit | Continue following the instructions for the diagnostic equipment | |||
| 2 | CODE WARNING LIGHT CHECK | All OK | Problems met | Operation | 
| Using the diagnostic equipment (Examiner or other instruments), carry out the active diagnosis for the CODE warning light | Continue to Step 3 | Connections not correct | Restore connections | |
| 3 | CHECKING THE CHECK CONTROL | All OK | Problems met | Operation | 
| Check the operation of the check control instrument see DESCRIPTION AND OPERATION: 5560 INSTRUMENT PANEL | Continue to Step 4 | Instrument not working | Replace the check control instrument Op. 5560B11 | |
| 4 | HECK ON CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | End of diagnosis | Fault persists | Search for the fault starting from another symptom' | |