3314777 - 5040A76 tandem pipe for delivery and return from evaporator rr
|  | Follow the safety instructions ( See assembly 5040A air conditioner coolant circuit ). | 
 Removing
		(
		Refitting
Removing
		(
		Refitting )
	
                                          Make sure that the ignition
is off (STOP position), then disconnect the negative battery terminal
(refer to op.  
                                            5530B10  battery - r+r
                                           ).
		)
	
                                          Make sure that the ignition
is off (STOP position), then disconnect the negative battery terminal
(refer to op.  
                                            5530B10  battery - r+r
                                           ).
                                       |  | Name | Connector | 
|---|---|---|
| - | Battery | A1B | 
|  | Seal the disconnected connectors, using suitable plugs, to prevent humidity and impurities from entering the system. | 

|  | Name | Country | 
|---|---|---|
| 1c | Key | 1.857.511.001 | 
|  | Seal the disconnected connectors, using suitable plugs, to prevent humidity and impurities from entering the system. | 
|  | Name | Connector | 
|---|---|---|
| 2 | Outside air intake flap actuator (motor)- | N82 | 
|  | Name | Connector | 
|---|---|---|
| 3 | Passenger compartment ventilation fan | N85 | 

 Refitting
		(
		Removing
Refitting
		(
		Removing )
	1. Place the evaporator inlet and outlet pipes (1a), complete with
the expansion valve (1b), back in their housings.2. Place the electrical wiring back in its housing and connect the
electrical connection for the air conditioning fan.3. Connect the electrical connection for the intake/recirculation
air flap actuator.4. Tighten the connectors (4a) and (4b) for the evaporator inlet
and outlet pipes, evaporator side to the recommended torque using
the tool (4c).
		)
	1. Place the evaporator inlet and outlet pipes (1a), complete with
the expansion valve (1b), back in their housings.2. Place the electrical wiring back in its housing and connect the
electrical connection for the air conditioning fan.3. Connect the electrical connection for the intake/recirculation
air flap actuator.4. Tighten the connectors (4a) and (4b) for the evaporator inlet
and outlet pipes, evaporator side to the recommended torque using
the tool (4c).|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| 4a | Connector | INLET PIPE TO EVAPORATOR | - | Evaporator side - | 
|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| 4b | Connector | OUTLET PIPE FROM EVAPORATOR | - | Evaporator side - | 
|  | Name | Country | 
|---|---|---|
| 4c | Key | 1.857.511.001 | 
|  | Replace the O-Ring seals for the connectors. Only use green coloured seals, resistant to R134A coolant fluid.Lubricate the threads of the connectors using anti-freeze. | 

|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| 1b | Nut | Pipe from drier filter to expansion valve. | M6 | Expansion valve side 0.8 - 1.0 | 
|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| 1b | Nut | Pipe from condenser to drier filter | M6 | Expansion valve side 0.8 - 1.0 | 