3315642 - E3070 CIGAR LIGHTER / CURRENT SOCKET - Functional description (Right hand drive)
Functional description
Power point / cigar lighter
P50
is
supplied with power (to pin 2) from an ignition-operated line (15/54)
protected by fuse
F7
from junction unit
B1
.
Pin 3 of socket
P50
supplies an
earth connection from
C15
.
The power point ring is lit (at pin 1) from
ignition-operated line (INT/A), protected by fuse
F5
of
junction unit
B1
. The same power supply also lights the
ring of supplementary power point
P51
, also at pin 1.
The resistance of supplementary socket
P51
receives power from pin 87 of relay
J61
.
The latter receives a supply directly from
the battery at pin 30, via the MAXIFUSE line
B5
(CENTR)
and fuse
F19
of junction unit
B1
.
The supply for the coil reaches pin 86 from
the line (15/54) via fuse
F7
; therefore the relay
J61
remains energized both when the ignition key
H1
is in the
on position and when it is in the starting position.
The pin of connector
P51
is connected
to earth
C30
.