3314769 - 5040A20 air conditioner compressor - r+r - includes fluid level check and top up if necessary
|  | Follow the safety instructions ( See assembly 5040A air conditioner coolant circuit ). | 
|  | Follow the safety instructions ( See assembly 5040A air conditioner coolant circuit ). | 
|  | Follow the safety instructions ( See assembly 5040A air conditioner coolant circuit ). | 
|  | Follow the safety instructions ( See assembly 5040A air conditioner coolant circuit ). | 
 Removing
		(
		Refitting
Removing
		(
		Refitting )
	Position the vehicle on the ramp
                                          Make sure that the ignition is off (STOP
position), then disconnect the negative battery terminal (refer
to op.  
                                            5530B10  battery - r+r
                                           ).
		)
	Position the vehicle on the ramp
                                          Make sure that the ignition is off (STOP
position), then disconnect the negative battery terminal (refer
to op.  
                                            5530B10  battery - r+r
                                           ).
                                       |  | Name | Connector | 
|---|---|---|
| - | Battery | A1B | 

|  | Name | Connector | 
|---|---|---|
| 1 | Air conditioning compressor engagement electro-magnet | L20 | 
|  | Seal the disconnected connectors, using suitable plugs, to prevent humidity and impurities from entering the system. | 


 Refitting
		(
		Removing
Refitting
		(
		Removing )
	If replacing the compressor, proceed as
follows.1. Remove the drain plug and drain the fluid from the compressor.
		)
	If replacing the compressor, proceed as
follows.1. Remove the drain plug and drain the fluid from the compressor.|  | Manually rotate the compressor to facilitate the removal of all the fluid. | 
|  | the fluid is extremely hygroscopic: avoid leaving the containers open. Avoid leaving the compressor or any other component disconnected from the system for longer than is strictly necessary. | 


|  | Replace the O-Ring seals for the connectors. Only use green coloured seals, resistant to R134A coolant fluid. Lubricate the thread of the connectors using anti-freeze. | 
|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| 1b | Bolt | Air conditioning compressor inlet/outlet pipes. | M10 | Air conditioning compressor side 4.1 - 5.0 | 

|  | Fastening | Component | Ø | Value(daNm) | 
|---|---|---|---|---|
| 1 | Bolt | AIR CONDITIONER ASSEMBLY COMPRESSOR | M10 | Support side 3.4 - 4.2 | 