3308737 - W01 HIGH CO EMISSIONS

The percentage of CO and/or HC is higher than the recommended figure.
Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation
Check the condition of the air filter Continue to Step 1 Filter element dirty or damaged Replace the filter element Op.   1048A14 
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socketCheck that there are no faults in the engine management control unit Continue to Step 2 An error is detected in the control unitContinue following the instructions for the diagnostic equipment
Lack of dialogue with the control unit Restore the connection between the engine management control unit and the diagnostic connector ( See   E5030  PETROL ENGINE ELECTRONIC MANAGEMENT ).
2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Using the diagnostic equipment (Examiner or other iinstruments) carry out the active diagnosis of:

  • vapour recovery solenoid valve
  • Injectors
Continue to Step 3 Connections faulty Restore the connection for the solenoid valve and the injectors with the control unit ( See   E5030  PETROL ENGINE ELECTRONIC MANAGEMENT ).
Solenoid valve faulty Replace the vapour recovery soleniod valve Op.   1080E24 
Injectors faulty Replace injectors Op.   1056B70 
3CHECKING LAMBDA SENSORAll OKProblems metOperation
Check that the Lambda sensor is working properly See Test   1080BA  Checking Lambda sensor Continue to Step 4 Lambda sensor not working properly Replace the Lambda sensor Op.   1080B60 
4CHECKING CATALYTIC CONVERTERAll OKProblems metOperation
Check that the catalytic converter is working properly Continue to Step 5 Catalytic converter not working properly Replace the catalytic converter Op.   1080B62 
5CHECKING AIR CIRCUITAll OKProblems metOperation
Check the condition and seal of the air supply circuit Continue to Step 6 Circuit component damagedReplace component (See Assembly 1048A)
6CHECKING FUEL PRESSUREAll OKProblems metOperation
Check the fuel supply pressure Op.   0510C10  Continue to Step 7 Pressure not correct Replace the fuel pump assembly Op.   1040A70 
7HECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'