3314314 - 1456B09 hot film air flow meter (debimeter) r + r (Automatic transmission)

Removing ( Refitting ) Make sure that the ignition is off (STOP position), then disconnect the negative battery terminal (refer to op.   5530B10  battery - r+r ).

NameConnector
-Battery  A1B 
 - 7040D12  engine front side cover (one) lh or rh - r r (left).  - 7040D14  engine bay rear side cover (one) lh or rh - r r (left).  - 1048A28  vacuum air circuit resonator pipe - r+r . 1. Disconnect the electrical connection from the air flow meter.

NameConnector
1Air flow meter  K41 
2. Undo the nuts (2a), remove the brackets (2b) and the air flow meter (2c).
Refitting ( Removing ) Fit the air flow meter and fix it using the brackets and the nuts.Connect the electrical connection to the air flow meter. - 1048A28  vacuum air circuit resonator pipe - r+r .  - 7040D14  engine bay rear side cover (one) lh or rh - r r (left).  - 7040D12  engine front side cover (one) lh or rh - r r (left). Connect the negative (-) battery terminal.