3314779 - 5040B14 air conditioner system multi-level pressure switch - r+r

Removing ( Refitting ) Make sure that the ignition is off (STOP position), then disconnect the negative battery terminal (refer to op.   5530B10  battery - r+r ).

NameConnector
-Battery  A1B 
 - 5040A10  Air conditioning refrigerant CIRCUIT - Draining and Refilling . 1. Disconnect the electrical connection for the air conditioning system multi-stage pressure switch.

NameConnector
14 stage pressure switch  K10 
2. Undo and remove the air conditioning system multi-stage pressure switch.
Refitting ( Removing ) Fit the multi-stage pressure switch and tighten it to the recommended torque.

FasteningComponentØValue(daNm)
--AIR CONDITION SYST MULTI LEVEL PRES SWTCM100.7 - 0.9
Connect the electrical connection to the multi-stage pressure switch. - 5040A10  Air conditioning refrigerant CIRCUIT - Draining and Refilling . Connect the negative (-) battery terminal