3314780 - 5040B30 expansion valve (tube orifice) - r+r

Follow the safety instructions (See 5040A - WARNINGS)
Removing ( Refitting )  - 5040A10  Air conditioning refrigerant CIRCUIT - Draining and Refilling .  - 5050B34  windscreen wiper arm/s complete with blade - r+r .  - 7055A18  Windscreen base TRIM - R.R. . 1. Undo the nuts (1a) and move the relay holder bracket (1b) aside.
1. Undo the nuts (1a) and disconnect the coolant fluid inlet and outlet pipes (1b) from the expansion valve and the fixing bands (1c).2. Undo the bolts (2a) and remove the expansion valve (2b) from the evaporator inlet and outlet pipes.
Seal the disconnected connectors, using suitable plugs, to prevent humidity and impurities from entering the system.
Refitting ( Removing ) 1. Place the expanssion valve (1a) back in its housing and fix it to the evaporator inlet and outlet pipes tightening the bolts (1b) to the recommended torque.

FasteningComponentØValue(daNm)
1bBoltEvaporator inlet/outlet pipesM6Expansion valve side 0.8 - 1.0
Replace the O-Ring seals for the connectors. Only use green coloured seals, resistant to R134A coolant fluid.Lubricate the threads of the connectors using anti-freeze.
2. Place the coolant fluid inlet and outlet pipes (2a) back in their housings and connect them to the expansion valve tightening the nuts (2b) to the recommended torque.

FasteningComponentØValue(daNm)
2bNutPipe from drier filter to expansion valve.M6Expansion valve side 0.8 - 1.0

FasteningComponentØValue(daNm)
2bNutPipe from condenser to drier filterM6Expansion valve side 0.8 - 1.0
Place the relay holder bracket back in its housing and fix it using the nuts. - 5040A10  Air conditioning refrigerant CIRCUIT - Draining and Refilling .  - 5040A14  air conditioner cooling circuit - check and repair any leaks by tightening fittings .  - 7055A18  Windscreen base TRIM - R.R. .  - 5050B34  windscreen wiper arm/s complete with blade - r+r .