3314792 - 5040C66 air conditioner evaporator - r+r with air conditioner box removed

Removing ( Refitting ) 1. Undo the bolts (1a) and separate the fan unit (1b) from the air conditioning unit (1c).2. Undo the bolts (2a) and remove the pollen filter filter element (2b).3. Undo the bolts (3a) and remove the bracket (3b).
1. Undo the connectors (1a) and disconnect the evaporator inlet and outlet pipes (1b) complete with expansion valve (1c).2. Undo the bolts fixing the air conditioning unit half casing.3. Cut the seal, then separate the two halves of the air conditioning casing.4. Remove the condensation drainage partition.5. Cut the sael and remove the air conditioning evaporator from the upper half of the casing.
Refitting ( Removing ) Place the air conditioning evaporator back in the upper half of the casing without damaging the seal.Place the condensation drainage partition back in its housing.Join the two halves of the casing, with the seal in place and fix it using the bolts.Connect the evaporator inlet and outlet pipes, complete with expansion valve, and fix it tightening the connectors to the recommended torque.

FasteningComponentØValue(daNm)
-ConnectorINLET PIPE TO EVAPORATOR-Evaporator side -

FasteningComponentØValue(daNm)
-ConnectorOUTLET PIPE FROM EVAPORATOR-Evaporator side -
Fit the bracket on the air conditioning unit and fix it using the bolts.Fit the pollen filter filter element and fix it using the bolts.Join the fan unit to the air conditioning unit and fix it using the bolts.