3308575 - A05 ALARM LED NOT WORKING

When the alarm is operated, the LED does not flash
Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect diagnostic equipment (Examiner or other instruments) to the diagnostic socket.

Check, in order:

  • no faults in alarm control unit
  • no faults in alarm receiver
Continue to Step 2 Error detected in the control unit or the receiverContinue following the instructions for the diagnostic equipment
Dialogue failure of the diagnostic equipment between the control unit and the receiver Restore the connection between the control unit and the diagnostic connector ( See   E7015  ALARM ).
2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
With the diagnostic equipment (Examiner or other instruments) carry out the active diagnosis of the operation of the LED. Continue to Step 3 LED not activated

Refit:

  • connections between alarm control unit and LED
  • LED earth ( See   E7015  ALARM )
LED not activated Replace the LED Op.   5580E18 
3HECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer present.End of diagnosisFault persistsSearch for the fault starting from another symptom'