3308579 - A25 ALARM VOLUMETRIC SURVEILLANCE NOT WORKING

When the alarm is operated the volumetric surveillance does not work
Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
WARNING: it is possible to exclude the volumetric surveillance from the operation of the system see DESCRIPTION AND OPERATION: 5580E anti-theft device ). Connect diagnostic equipment (Examiner or other instruments) to the diagnostic socket.

Check, in order:

  • no faults in alarm control unit
  • no faults in alarm receiver
Continue to Step 2 Error detected in the control unit or the receiverContinue following the instructions for the diagnostic equipment
Dialogue failure of the diagnostic equipment between the control unit and the receiver Restore the connection between the control unit and the diagnostic connector ( See   E7015  ALARM ).
2CHECK VOLUMETRIC SENSORSAll OKProblems metOperation

Check, in order:

  • operation of volumetric sensors
  • connections between sensors and alarm control unit
See   E7015  ALARM ).
Continue to Step 3 Sensor faulty Replace sensor Op. 5580E22 .
Connections brokenRestore connections
3HECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'