3308672 - L01 CLIMATE CONTROL NOT WORKING / UNDER NO CIRCUMSTANCES

None of the climate control system controls works. The ICS screen displays the message 'climate control system malfunction'.
Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect diagnostic equipment (Examiner or other instruments) to the diagnostic socket. Check that there are no faults in the climate control control unit Continue to Step 2 An error is detected in the control unit Continue following the instructions for the diagnostic equipment Continue to Step 4
Lack of dialogue with the control unit Restore connection between climate control control unit and diagnostic connector ( See   E6020  AIR CONDITIONING ) Continue to Step 4
Specific software not available Continue to Step 2
2CHECKING POWER SUPPLYAll OKProblems metOperation
Check that the climate control system control unit and the ICS control button assembly are correctly supplied ( See   E6020  AIR CONDITIONING ) Continue to Step 3 Connections not correctRestore connections
Component defectiveReplace the component involved (if a fuse is involved, search for the cause of the problem)
3CHECK ICS CONTROL UNIT COMMUNICATIONAll OKProblems metOperation
Check the condition of the interface line between ICS pushbutton assembly and climate control system control unit ( See   E6020  AIR CONDITIONING ) Continue to Step 4 Connections not correctRestore connections
Component defectiveReplace the component involved (if it is a fuse, search for the cause of the problem)
4HECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'