3308678 - L12 CLIMATE CONTROL TOO COLD

The fan works properly and sends air into the interior compartment in accordance with the set flows, but this air reduces the temperature in the interior compartment too much.
Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect diagnostic equipment (Examiner or other instruments) to the diagnostic socket. Check that there are no faults in the climate control control unit Continue to Step 2 An error is detected in the control unitContinue following the instructions for the diagnostic equipment
Lack of dialogue with the control unit Restore connection between climate control control unit and diagnostic connector ( See   E6020  AIR CONDITIONING )
Specific software not available Continue to Step 3
2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the diagnostic equipment (Examiner or other instruments) carry out the active diagnosis for the mixture motor Continue to Step 4 Mixing motor connection faulty Restore the connections ( See   E6020  AIR CONDITIONING ) Continue to Step 4
Mixture motor faulty Replace the mixture motor Op.   5040D77  Continue to Step 4
3MIXTURE MOTOR CHECKAll OKProblems metOperation
Check the operation of the mixture motor Continue to Step 4 Mixing motor connection faulty Restore the connections ( See   E6020  AIR CONDITIONING )
Mixture motor faulty Replace the mixture motor Op.   5040D77 
44 STAGE PRESSURE SWITCH CHECKAll OKProblems metOperation
Check the 4 stage pressure switch: See Test   5040BA  Check operation of four stage pressure switch Continue to Step 5 Pressure switch defective Replace the pressure switch Op.   5040B14 
Connections not correct Restore the connections ( See   E6021  COMPRESSOR ENGAGEMENT )
5CHECKING SYSTEM PRESSUREAll OKProblems metOperation
Chec the system pressures: See Test   5040B  Check on operation of air conditioning system (pressures) Continue to Step 6 High pressure does not increase or low pressure decreases too much: insufficient fluid Re-pressurize the system: Op.   5040A10 
High pressure continues to increase: too much fluid Re-pressurize the system: Op.   5040A10 
6HECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'