3308679 - L15 CLIMATE CONTROL NOT HEATING

The fan works properly and sends air into the interior compartment in accordance with the set flows, but this air does not ensure the required heating.
Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect diagnostic equipment (Examiner or other instruments) to the diagnostic socket. Check that there are no faults in the climate control control unit Continue to Step 2 An error is detected in the control unitContinue following the instructions for the diagnostic equipment
Lack of dialogue with the control unit Restore connection between climate control control unit and diagnostic connector ( See   E6020  AIR CONDITIONING )
Specific software not available Continue to Step 3
2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the diagnostic equipment (Examiner or other instruments) carry out the active diagnosis for the mixture motor Continue to Step 4 Mixing motor connection faulty Restore the connections ( See   E6020  AIR CONDITIONING ) Continue to Step 4
Mixture motor faulty Replace the mixture motor Op.   5040D77  Continue to Step 4
Mixture motor flap faulty Replace mixture motor flap Op.   5040C24  Continue to Step 4
3MIXTURE MOTOR CHECKAll OKProblems metOperation
Check correct operation of mixture motor Continue to Step 4 Mixture motor faulty Replace the mixture motor Op.   5040D77 
Mixture motor flap faulty Replace mixture motor flap Op.   5040C24 
4HEATER PIPE CHECKAll OKProblems metOperation
Check the efficiency and seal of the supply and return pipes to/from the heater.When the engine is hot, the pipes must be hot. Continue to Step 5 Pipes not connectedRestore the correct connection
Pipes dirty or obstructedClean the pipes or replace them
5CHECKING HEATER RADIATORAll OKProblems metOperation
Check the seal of the heater radiator Continue to Step 6 Pipes not connectedRestore the correct connection
Radiator dirty or obstructed Clean the radiator or replace it Op.   5040C50 
6HECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'