3308681 - L30 SUPPLEMENTARY HEATER WILL NOT COME ON

the heater only comes on when the engine is running, with engine water temperature <72° C and external air temperature <= 5° C.
Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect diagnostic equipment (Examiner or other instruments) to the diagnostic socket. Check that there are no faults in the combustion control unit Continue to Step 2 An error is detected in the control unitContinue following the instructions for the diagnostic equipment
Lack of dialogue with the control unit Restore the connection between the combustion control unit and the diagnostic connector ( See   E6015  ADDITIONAL HEATER )
2CHECK SUPPLY RELAYAll OKProblems metOperation
With the ignition on (MAR), check that the combustion control unit supply relay is working Continue to Step 3 Relay faulty Replace the mixture motor Op.   5040D77 
Lack of continuity Restore the connections ( See   E6015  ADDITIONAL HEATER )
3CHECK THAT BOILER COMES ONAll OKProblems metOperation
With the water temperature <72° C, bridge the external air sensor, start the engine and check that the boiler comes on Continue to Step 4 Boiler does not come on Restore the connections ( See   E6020  AIR CONDITIONING )
4CHECK EXTERNAL AIR TEMPERATURE SENSORAll OKProblems metOperation
Check the operation of the outside air temperature sensor. See Test   5020MA  Check external air temperature sensor for the additional heater Continue to Step 5 Sensor faulty Replace sensor P Op.   5010D12 
5CHECK ALTERNATOR D+ SIGNALAll OKProblems metOperation
Check the presence of the alternator supply D+ signal Continue to Step 6 Alternator signal interrupted Restore the connections ( See   E6020  AIR CONDITIONING ), if necessary overhaul the alternator
6CHECK FUEL PUMPAll OKProblems metOperation
Check operation of fuel pump: See Test   5020MB  Check operation of pump dispensing/delivering fuel to supplementary stand-alone heater Continue to Step 7 Fuel pump faulty Replace additional fuel pump Op.   5020M30 
Connections not correct Restore the connections ( See   E6020  AIR CONDITIONING )
7CHECK AIR LEAKSAll OKProblems metOperation
Check for incorrect intake of burnt air Continue to Step 8 Boiler unit leakingRepair the leak
Faulty burner Replace Vedere burner unit Op.   5020M14 
Faulty exhaust pipesRestore correct operation
8CHECK COMBUSTION AIR FANAll OKProblems metOperation
Check operation of combustion air fan: See Test   5020MD  Check supplementary stand-alone heater fuel air fan Continue to Step 9 Overload and fan outlet command (i>500 mA) because of short circuit Replace combustion control unit Op.   5020M14 
Fan fault Replace combustion air fan Op.   5020M14 
9CHECK PLUGAll OKProblems metOperation
Check operation of plug: See Test   5020MC  Check additional stand-alone heater plug Continue to Step 10 Plug in A.C. or D.C. Replace plug burner kit Op.   5020M14 
10HECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'