3308683 - L32 EXCESSIVE SMOKINESS' AT EXHAUST TERMINAL

Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect diagnostic equipment (Examiner or other instruments) to the diagnostic socket. Check that there are no faults in the combustion control unit Continue to Step 2 An error is detected in the control unitContinue following the instructions for the diagnostic equipment
Lack of dialogue with the control unit Restore the connection between the combustion control unit and the diagnostic connector ( See   E6015  ADDITIONAL HEATER )
2CHECK FUEL PUMPAll OKProblems metOperation
Check operation of fuel pump: See Test   5020MB  Check operation of pump dispensing/delivering fuel to supplementary stand-alone heater Continue to Step 3 Fuel pump faulty Replace the fuel pump Op.   5020M30 
3CHECK PLUGAll OKProblems metOperation
Check operation of plug: See Test   5020MC  Check additional stand-alone heater plug Continue to Step 4 Plug faulty Replace plug burner kit Op.   5020M14 
4CHECK COMBUSTION AIR FANAll OKProblems metOperation
Check operation of combustion air fan: See Test   5020MD  Check supplementary stand-alone heater fuel air fan Continue to Step 5 Fan fault Replace fan Op.   5020M14 
5HECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsSearch for the fault starting from another symptom'