3314987 - 7005C52 interior opening handle - r r
Removing ( Refitting ) - 7005A04 front side door water guard protection - r r or replace with door panel removed 1. Release cable (1a) from retainer (1b) on the handle and from retaining clip (1c).2. Unscrew both bolts retaining the handle to the door frame.2. Remove the handle.
Refitting
(
Removing
)
Check that the handle is undamaged.Connect the door opening cable to the handle.Fit the handle.Screw in both retaining bolts. Check the handle and link are working properly.- 7005A04 front side door water guard protection - r r or replace
with door panel removed