3315427 - 1060B Check low pressure fuel circuit
Connect the pressure transducer of the Examiner/SDC diagnostic instrument between the diesel filter (1a) and the pressure pump (1b).Turn the ignition on.Check that, within 30 seconds, the pressure gauge's
reading is below 1.8-3.0 bar.
The pump in the tank stops after 30 seconds. |
Make sure that the cocks and adjustment screws next to the pressure gauge are open (except those on pipes not connected to the system). |