3314795 - 5040C84 air blender flap - r r

Follow the safety instructions (See 5040A - WARNINGS)
Removing ( Refitting ) Make sure that the ignition is off (STOP position), then disconnect the negative battery terminal (refer to op.   5530B10  battery - r+r ).

NameConnector
-Battery  A1B 
 - 5040A10  Air conditioning refrigerant CIRCUIT - Draining and Refilling .  - 5050B34  windscreen wiper arm/s complete with blade - r+r .  - 5050B38  windscreen wiper assembly - r+r or repair .  - 7055A18  Windscreen base TRIM - R.R. .  - 5010B21  climate control unit compartment - r r .  - 5040C10  air conditioner box - r+r . 1. Undo the bolts (1a) and remove the duct (1b).
1. At the bench, undo the bolts (1a) and remove the actuator for the mixed air flap (1b).Position the mixed air flap in the "full hot" position.2. Remove the hinge pin for the mixed air flap using a suitable drift.3. Release the connecting rod (3a) and remove the mixed air half flaps (3b).
Refitting ( Removing ) Place the mixed air half flaps back in their housings and connect them using the rod.Fit the hinge pin for the mixed air flap using a suitable drift.Fit the mixed air flap actuator and fix it using the bolts.
Check the actuator timing with the mixture flap ring nut.
Apply sealant to the surface where the duct and the distributor unit are matched.Fit the duct and fix it using the bolts. - 5040C10  air conditioner box - r+r .  - 5010B21  climate control unit compartment - r r .  - 7055A18  Windscreen base TRIM - R.R. .  - 5050B38  windscreen wiper assembly - r+r or repair .  - 5050B34  windscreen wiper arm/s complete with blade - r+r .  - 5040A10  Air conditioning refrigerant CIRCUIT - Draining and Refilling . Connect the negative (-) battery terminal.