3315453 - 5040B Check on operation of air conditioning system (pressures)
The test must be carried out at an ambient temperature of between 18 ° C and 30 ° C. |
Make sure that the air conditioner
is switched off (ECON button pressed).Switch on recirculation (button pressed).Press the fan speed selector until 3 solid
bars are displayed on the ICS monitor.Press the temperature selector until it
is at the coldest setting (LOW).Press the air distribution selector until
distribution is in the front position.
Check on the recharging device's
low and high pressure gauges, that the pressure is within 5-6 bar.Switch on the air conditioner (AUTO button pressed).Check that within one minute, the low pressure gauge
reading is 2.5-3.0 bar and the high pressure gauge reading is 15-16
bar.Wait for the engine cooling fan to come
on and check that the low pressure gauge reading is 1.5-1.8 bar
and the high pressure gauge reading is 10-12 bar.