3314366 - 1060G10 flow meter - r r

Removing ( Refitting ) Ensure that the ignition key is in the OFF position, then disconnect the negative battery terminal (-).

NameConnector
-Battery  A1B 
Proceed with removal  - 7040D12  engine front side cover (one) lh or rh - r r (Left side). Proceed with removal  - 7040D30  engine bay front beam cover - r r . 1. Loosen the band and disconnect the turbocharger air inlet pipe, air flow meter side.2. Disconnect the electrical connection from the air flow meter.

NameConnector
2Air flow meter  K41 
3. Undo the nuts (3a) and remove the air flow meter mounting brackets (3b).4. Remove the air flow meter.
Refitting ( Removing ) Refit the air flow meter in its seating.Fit the brackets securing the air flow meter in their seatings and secure them with their nuts.Connect the electrical connection to the air flow meter.Connect the air intake pipe to the turbocharger, air flow meter side, and tighten the band. Proceed with refitting  - 7040D30  engine bay front beam cover - r r . Proceed with the refitting  - 7040D12  engine front side cover (one) lh or rh - r r (Left side). Connect the negative (-) battery terminal.