3314585 - 3330D30 vacuum pump - r+r

Removing ( Refitting ) Proceed with removal  - 1016A10  sound-proofing cover - r + r . 1. Loosen the band and disconnect the vacuum pipe from the vacuum pump.2. Undo the bolts (2a) and remove the vacuum unit (2b).3. Remove the gasket.
Refitting ( Removing ) 1. Place the vacuum unit (1a), complete with gasket (1b), back in its housing and secure it tightening the bolts (1c) to the recommended torque.

FasteningComponentØValue(daNm)
1c----
2. Connect the vacuum intake pipe to the vacuum unit and tighten the band.
Proceed with refitting  - 1016A10  sound-proofing cover - r + r .