3314950 - 5580E50 antitheft device volumetric sensor r r following electrical circuit check

Removing ( Refitting ) 1. Press in the direction of the arrow and lower the volumetric sensor unit (1a), releasing it from the inner retainers (1b) and (1c).
1. Disconnect electrical connections (1a) and (1b).

NameConnector
1aHands-free microphone  P26 

NameConnector
1bAlarm volumetric sensors assembly  K62 
2. Keep the volumetric sensor unit.
Refitting ( Removing ) Check that the sensor unit is not damaged.Connect the electrical connections .Place the sensor unit in position attaching the retainers.Using the Examiner, check that the system has not picked up errors during the operation.