3315732 - E6020 AIR CONDITIONING - Functional description

Functional description

Climate control unit M70 is supplied when the ignition is turned on (INT/A) at pin 11 of connector B by the line protected by fuse T25 of B45 controlled by the relay T24 and protected by fuse F78 of B45. The power supply comes directly from the battery to pin 15 of connector C through fuse F19 of junction unit B2. Pin 1 of connector C of M70 is earthed. The exterior temperature sensor is located on left door mirror P60 ; The sensor is connected to pins 1 and 7 of connector A of M70. Control unit M70 is also connected to sensors K87 (lower treated air), K88 (upper treated air) which are connected to pins 3-5 and 11-12 of connector A of M70 respectively. Sensor K89 (passenger compartment air) is fitted with a fan motor controlled by the ignition so that the temperature reading is not affected by the motionless and thus warmer air inside the dashboard. the motor is connected to the control unit, to pins 10 and 12 of connector B; the actual sensor is connected to the control unit at pins 13 and 8 of connector A. Solar radiation sensor K90 is connected to pins 6 and 15 of connector A of M70 . The air conditioning system is equipped with three activators for recirculation ( N82 ), air mixing ( N81 ) and air distribution ( N80 ). Recirculation actuator N82 is controlled by control unit M70 , via pins 3 and 4 of connector B. Recirculation actuator N82 is controlled by control unit M70, via pins 1 and 2 of connector B. Actuator N81 receives a power supply at pins 5 and 3 and a control potentiometer earth signal via pins 20 and 14 connector A of control unit M70 which receives the feed-back signal at pin 16 of connector A. Distribution actuator N80 is controlled from control unit M70 via pins 7 and 8 of connector B. Actuator N80 receives power at pins 6 and 4 and an earth signal for the control potentiometer via pins 18 and 2 of connector A of control unit M70 which receives the feed-back signal at pin 17 of connector A. Fan N85 is operated at different speeds by its internal governor; it receives input control signals from control unit M70 from pins 3, 7 and 8 of connector C and transforms them into signals for the operation of the fan. The fan unit N85 is supplied by the line protected by fuse F8 via the contact for relay T8 of the engine compartment junction unit B1. Pin 5 of connector B of M70 receives a speedometer signal from instrument E50. A heated rear window activation command is transmitted by control unit M70 from pin 9 of connector B whilst pin 11 of connector C receives the on signal for the relevant LED. See E3030  HEATED REAR WINDSCREEN AND DOOR MIRROR DEFROSTING Pin 6 of connector B controls activation of the compressor  See E6021  COMPRESSOR ENGAGEMENT . Climate control unit H80 communicates with control unit M70 via a serial connection line: from pin 12 of connector C of M70 to pin 5 of H80 via junction D90. Climate control unit H80 is also connected from pin 6 to ICS display E60 (pin 15 connector B) via a special serial connection line. The control unit M70 is equipped with a self-diagnostic unit that may be used by connecting the unit to connector R10 pin 9; it receives signals from pin 12 of connector C of M70 via the serial connection line between control unit M70 and climate control system unit H80 and from there is connected to the ICS display E60. See E8010  DIAGNOSTIC MULTIPLE CONNECTOR