3308630 - F30 ANTI-SLIP FUNCTION NOT WORKING - ASR
During strong acceleration, the front wheels skid, even with the ASR lamp on the instrument panel flashing.| Results of the tests | ||||
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
|---|---|---|---|---|
| Connect
diagnostic equipment (Examiner or other instruments) to the diagnostic
socket. Verify: 
 | Continue to Step 2 | An error is detected in the control unit | Continue following the instructions for the diagnostic equipment | |
| Lack of dialogue with the control unit | Restore the connection between the ABS control unit and diagnostic connector ( See E7020 ABS ) | |||
| 2 | ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation | 
| Using the diagnostic equipment (Examiner or other iinstruments) carry out the active diagnosis of: 
 | Continue to Step 3 | Pump and/or solenoids faulty | Replace electrohydraulic unit-electronic control unit Op. 3340A12 | |
| 3 | CHECK PAD TYPE AND SURFACE | All OK | Problems met | Operation | 
| Verify: 
 | Continue to Step 4 | Friction surfaces vitrified or with traces of oil or grease | Clean and eliminate the causes of the problem | |
| Front pads damaged or wrong type | Replace front pads Op. 3310A60 | |||
| 4 | CHECK DISCS | All OK | Problems met | Operation | 
| Check the condition of the brake discs | Continue to Step 5 | Front discs worn or damaged | Skim or if necessary replace front discs Op. 3310A48 | |
| 5 | CHECKING BRAKE CALIPERS | All OK | Problems met | Operation | 
| Check that the brake caliper pistons run freely | Continue to Step 6 | Front caliper pistons seized | Replace front brake calipers Op. 3310A30 | |
| 6 | CHECK BRAKE PIPES/HOSES AND BLEEDING | All OK | Problems met | Operation | 
| Visually check that there are no kinks or restrictions in the brake pipes, bleed the system and check that fluid emerges from the bleed screws as normal | Continue to Step 7 | There are kinks or restrictions, fluid does not come out normally | Replace the faulty section of pipe | |
| 7 | HECK ON CORRECT OPERATION | All OK | Problems met | Operation | 
| Check that the fault is no longer present | End of diagnosis | Fault persists | Search for the fault starting from another symptom' | |