2752905 - 5040D76 air contitioner distribution flap control motor - r r
 Removing
		(
		Refitting
Removing
		(
		Refitting )
	Disconnect the battery negative
terminal.Disconnect the electrical connection.
		)
	Disconnect the battery negative
terminal.Disconnect the electrical connection.|  | Name | Connector | 
|---|---|---|
| - | Air distribution flap actuator | N80 | 

 Refitting
		(
		Removing
Refitting
		(
		Removing )
	1. Fit the air conditioner air distribution flap motor, checking
that the references on the motor sprocket (1a and the distribution
flaps sprocket (1b are correctly positioned.
		)
	1. Fit the air conditioner air distribution flap motor, checking
that the references on the motor sprocket (1a and the distribution
flaps sprocket (1b are correctly positioned.|  | If the distribution flap motor has to be replaced, the new component has to undergo the Proxi initialisation procedure using the diagnostic station (Examiner). | 

|  | Name | Connector | 
|---|---|---|
| - | Air distribution flap actuator | N80 |