169000224 - N65 CONNECT NOT WORKING

The Connect screen does not come on (goes on and off sporadically)
1ELECTRICAL CONNECTION CHECKAll OKProblems encounteredOperation
Withdraw the Connect unit from the facia and check the connectionsCheck the condition of the fuse on the Connect body.Check that the correct power supplies are present at the Connect connectors    See Test 5580PO CONNECT POWER SUPPLY CHECK+C141Move on to Step 2

  • Fuse blown
  • No power supply
  • Incorrect earth connection

  • Renew the blown fuse after ascertaining the cause
  • Restore correct power supply See E4090 NAVIGATOR
  • Restore the correct earth connection See E4090 NAVIGATOR
2CHECK ON CORRECT OPERATIONAll OKProblems encounteredOperation
Check that it is working properlyEnd of diagnosisThe fault persistsReplace Connect