169000686 - Z86 SOLENOID VALVE OVERHEATING ERROR

The diagnostic equipment signals the following error "C1098 - Solenoid valves overheating"
This error is signalled if they are activated for too long in order to preserve them.
1SOLENOID VALVE COOLINGAll OKProblems encounteredOperation
Avoid activating the solenoids with the diagnostic tester for a few minutes.Blow on the electrohydraulic control unit with compressed airMove on to Step 2 1
2CHECK ON CORRECT OPERATIONAll OKProblems encounteredOperation
Delete the errors using the diagnostic equipment.Carry out a road test    See Test 3340OA A.B.S. SYSTEM ACTUATION CHECKto ensure that the control unit checks whether there are any errors still present.Return to the workshop and check that the fault is no longer present using the diagnostic equipmentEnd of diagnosis